User Tools

Site Tools


Sidebar


miniature_motors:installation

Installation

Slider distance for parallel drive mounting

Whne the application needs tandem parallel configuration of the integrated drive linear motor, the two or more actuator must mounted guarantee the safety distance L3 to avoid the interaction between magnetic sliders.

MOTOR MODEL NO INTERACTION MEDIUM INTERACTION STRONG INTERACTION
NLi080> 35 mm > 15 mm to 35 mm < 15 mm
NLi120> 65 mm > 45 mm to 65 mm < 45 mm

NL080Q Fixing points

NL080X Fixing points

NL120Q Fixing points

NL120X Fixing points

NL080Q/X slider fixing point

Slider has M4 threaded hole at each slider ends.

slider_8.jpg

NL120QX slider fixing point

Slider has M4 threaded hole at each slider ends.

slider_12.jpg

miniature_motors/installation.txt · Last modified: 2022/11/21 12:47 by mgavesi